Technische Daten Wanderfeldröhre UV-1004 :


TRAVELLING-WAVE TUBE UV-1004


PRINCIPAL TECHNICAL DATA


Denomination of parameter, measurement unit Significances of parameters
allowable operating actual
minimal maximum
1. Filament voltage, V nom-5% nom+5%  
2. Control electrode voltage, V nom-1% nom+1%  
3. First anode voltage, V nom-1% nom+1%  
4. Slow-wave structure voltage, approximately, V 300±0.5% 500±0.5%  
5. Collector voltage, V 600-5% 600+5% 600
6. Filament current, A 0.5 1  
7. Slow-wave structure current, µA -5 +30  
8. Collector current, µA 150 600  
9. Operating wavelength range, cm 8 - 12.2 8 - 12.2
10. Noise factor, dB 10  
11. Power gain, dB 25  
12. Gain flatness, dB 8  
13. Solenoid magnetic field strength of the cathode region, Oe 600 600
14. Total starting time, min 1.5
15. Minimum operating time, h 2000
16. Temperature of the TWT case, °C +200
17. Ambient temperature, °C -60

Notes:

  1. Instability of the supplying voltage must not exceed the significances indicated in the present table.
  2. Non-nominal significance of a parameter indicated in the column "Significances of parameters actual".

ELECTRODES-TO-LEADS CONNECTION DIAGRAM

UV-1004 Wanderfeldröhre Designation of leads Denomination of electrodes and other elements of diagram Number of leads
A2 Second anode,
slow-wave structure
5
A1 First anode 4
P Heater 2
PK Cathode, heater 6
Y Control electrode 3
Kl Collector, case 1
I Input  
II Output  

OPERATION INSTRUCTIONS

During the TWT operation all electrode voltage must be set to their nominal values excluding the slow-wave structure voltage which is adjusted by the minimum value of the power gain or the minimum value of the noise factor and the minimum value of the gain flatness simultaneously.
The nominal electrical regime is chosen by the producer for a given specimen of the TWT in the following limits:

filament voltage from 2 to 3.3 V;
control electrode voltage from 2 to 15 V;1
first anode voltage from 30 to 150 V;
slow-wave structure voltage from 300 to 500 V;
collector voltage of 600 V.

focusing magnetic field strength at the cathode region of 600 Oe.
All voltages are given relatively the cathode.
Special attention should be paid to setting the nominal filament voltage as stated in the certificate.
The TWT collector is connected to the case and during operation it must be grounded.
The TWT has the natural cooling.
When mounting the TWT in apparatus it is allowed to shorten the flexible leads the supply up to 20 mm.

SWITCH ON PROCEDURE

Switch on the filament voltage, set its nominal value and heat the cathode during 1 - 2 min.
Switch on the solenoid supply voltage. It is permitted its switching on simultaneously with the switching on of the filament voltage.
Switch on the high voltage, set the collector voltage and the slow-wave structure voltage to their nominal values.
Gradually increasing the control electrode voltage and the first anode voltage up to the nominal values, selecting the TWT's position in the solenoid, adjust it so that the slow-wave structure current has minimum value.
When adjusting the TWT it is not advisable to allow the exceeding of the slow-wave structure current more than 30 µA.
It is permitted to exceed the slow-wave structure current up to 100 µA during not more than 1 - 2 s.
Fix the TWT in the solenoid.
Apply the signal at the TWT input.
Adjust the TWT at the best sensitivity by the slow-wave structure voltage and in case of need by the TWT turn in the solenoid and by the matching transformer.
By repeated switching on of the adjusted TWT it is permitted to switch on simultaneously all supplying voltages after the cathode has been heater.

SWITCH OFF PROCEDURE

Switch off the first anode voltage.
Switch off the control electrode voltage.
Switch off the slow-wave structure voltage and the collector voltage. It is permitted to switch off all high voltage simultaneously.
Switch off the filament voltage. The filament is sure to be switched off the last.Switch off the solenoid supply voltage.




Wanderfeldröhre, TWT, UV-1004, russisch УВ-1004

Wanderfeldröhre, TWT, UV-1004, russisch УВ-1004

Wanderfeldröhre, TWT, UV-1004, russisch УВ-1004

Wanderfeldröhre, TWT, UV-1004, russisch УВ-1004

Wanderfeldröhre, TWT, UV-1004, russisch УВ-1004

Wanderfeldröhre, TWT, UV-1004, russisch УВ-1004




Allgemeines zur Wanderfeldröhre:

Die Wanderfeldröhre gehört zu den Laufzeitröhren.
Eine Laufzeitröhre ist eine Elektronenröhren zur Erzeugung oder -Verstärkung von Mikrowellen. Laufzeitröhren finden also ihre Anwendung in der Hochfrequenztechnik.

Bei den Laufzeitröhren sind die Entladungssyteme so konstruiert, daß Laufzeiteffekte das Funktionieren der Röhre bewirken.
Zunächst wird eine homogene Elektronenströmung konstanter Geschwindigkeit erzeugt, deren Elektronen dann einem steuernden elektrischen HF-Feld ausgesetzt werden, in dem sie je nach Startphase beschleunigt oder verzögert werden.

Bei den Langzeitröhren unterscheidet man zwischen Triftröhren und Lauffeldröhren.
In der Praxis verwendete Laufzeitröhren sind Zweikammer- und Mehrkammerklystrons, Wanderfeldröhren, Rückwärtswellenröhren und Magnetrons sowie gewisse Hybridformen wie Wanderfeldklystrons.

Die Wanderfeldröhre dient der Verstärkung elektrischer Signale. Der Elektronenstrahl wird durch ein nicht mitgezeichnetes homogenes axiales Magnetfeld, herrührend von einem auf möglichst gewicht- und raumsparende Weise gestalteten Elektro- oder Permanentmagneten, oder auch von einem periodischen Permanentfeld, fokussiert und zum Elektronenauffänger geführt. Die zu verstärkende HF-Leistung wird katodenseitig auf die Wendelleitung gekoppelt, wohingegen die verstärkte HF-Leistung kollektorseitig ausgekoppelt wird.
Wanderfeldröhren werden wegen ihrer guten Linearität (Breitbandeigenschaften) und Rauscharmut und wegen des großen Leistungsspielraumes mannigfaltig eingesetzt, z.B. in Bodenstationen für Satellitenfunk mit Dauerstrichleistungen im kW-Bereich, als Satellitenröhren (bis herab zu 20 W interessant; 650g Masse) und für Richtfunktechnik (2700 Kanäle bei 6 ... 7 GHz) sowie für die Radar-Impulstechnik mit Impulsleistungen bis zu mehreren MW. Die Wanderfeldröhre ist ein weit verbreitetes Bauteil in der Radartechnik.
Der Frequenzbereich der Verstärkung ist kleiner als 0,05 dB x MHz hoch -1 im ganzen Bereich, bei optimaler Frequenz sogar noch eine Zehnerpotenz geringer.
Die Zuverlässigkeit der Wanderfeldröhren ist groß, die Lebensdauer dieser Laufzeitröhren liegt bei Größenordnungen von 20 000 Stunden.